Support

Safety instruction

1.Prior to operation, it is imperative that the water pump and the controller be correctly grounded. Failure to do so will expose users to a grave risk of electric shock.

2.Solar water pumps must be connected to our own controllers.It is strictly prohibited to test the pump without a controller. Otherwise, the motor will be burnt out.

3. It is strictly forbidden to connect wires when the power is on,otherwise there will be a risk of electric shock.

4.When the controller is running, it is strictly forbidden to touch or plug the power cord and output motor cord.

User Manual Download

Fault Information and Troubleshooting Method

Fault Code Fault Description Causes and Solutions of Fault Recovery Procedure
P0 Hardware   over-current The controller output loop is short-circuited.
Controller driver module error Starting the rotating motor
Check for open circuits in the UVW three-phase system. Reconnect the wiring after power is restored to ensure proper installation of the UVW.
After the power is cut off, remove the motor wires and power the controller again. If the P0 fault still occurs, the controller hardware is damaged.
Manual  button  reset  is  required,  or  the device will be cleared when powered off
P1 Backwater  protection The  motor pump  is  in  the  process  of reverse  water flow. Wait for the water to flow back before restarting.
If the  pipeline  is  not  in  the  return  water  state,  or  the  fault  is reported  after  more  than  10  minutes  of return  water,  check  the motor output UVW.
Check for any leakage or short circuits in the ground.
The first 5 failures will be displayed for 90 seconds and then automatically cleared and restarted. Subsequent restarts will occur every 30 minutes.
P42 Input phase loss protection The three-phase power supply RST input is open. Reconnect the wiring after power is restored to ensure reliable RST contact. Clear automatically after recovery
P43 Output phase loss protection The UVW three-phase motor has an open circuit. Reconnect the wiring after power is restored to ensure reliable UVW contact. After a failure, the first 5 attempts will wait 30 seconds  to  clear  the  fault  and  restart.  Starting from the 6th attempt, the system will wait.
30 Clear the fault and restart.
P44 Startup failure Check for foreign objects in the pump impeller and abnormal motor load. After the failure, the first 5 times wait 30 seconds to clear the fault and restart, the 6th time wait 30 minutes to clear the fault and restart.
P45 Out-of-step protection The motor model is not compatible.  Select a compatible pump. After the failure, the first 5 times wait 30 seconds to clear the fault and restart, the 6th time wait 30 minutes to clear the fault and restart.
P46 Loose-speed protection The motor model is not compatible.  Select a compatible pump. The pump extension cable is too long. Reduce the extension cable.
The power supply is too low. Increase the power supply.
The pump bearing is stuck. Clean the pump bearing.
After the failure, the first 5 times wait 30 seconds to clear the fault and restart, the 6th time wait 30 minutes to clear the fault and restart.
P47 Over-speed protection The pump extension cable is too long. Reduce the extension cable.
The pump bearing is stuck. Clean the pump bearing.
After the failure, the first 5 times wait 30 seconds to clear the fault and restart, the 6th time wait 30 minutes to clear the fault and restart.
P48 Dry running protection / Load-drop protection The air in the pump has not been completely expelled. Cut off the power, power on again after 30 seconds, and start the pump to drain the air.
If the motor's  operating power  is  lower than the preset  dry-run protection power value, adjust the power value from P0.5 to P0.8 in the menu.
The time is determined by the P 1.9 setting, and when the
time reaches
After that, clear the error and restart.
P51 High  voltage  protection The voltage input is too high. Refer to the electrical characteristics ofthe corresponding model for normal distribution. Restore the voltage to normal and clear immediately
P59 Power supply mode
selection error
If the  controller  cannot  detect  the  corresponding power input when selecting the power supply mode set by P0.2,it will  report  this  fault  code.  Check whether the power supply mode selection matches the controller wiring. Clear automatically after recovery
P60 High  temperature  protection The MCU temperature in the controller exceeds
85℃
Clear    automatically    when    temperature normal
P63 Pressure  sensing  over pressure protection Check if the constant pressure setting is correct and verify  that  the  pressure  sensor  wiring  is  properly connected. Restore pressure and eliminate the fault
P64 Pressure   sensing   break wire protection Check if the pressure  sensor model is correct and verify that the sensor wiring is properly connected. Restore normal pressure feedback and eliminate the fault
PL Low voltage protection /Power low The voltage input is too low. Refer to the electrical characteristics ofthe corresponding model for normal distribution.
The solar panel is not properly selected. Refer to the recommendations for correct selection.
Clear automatically after recovery
E8 Current Sampling Failure •Cut off the power and restart after 30 seconds. Restart the power
ALARM Reverse connection protect •Exchange the positive and negative wire. Restart the power